Goodman Heaters, Furnaces, Air Conditioners, Furnaces Manuals & Troubleshooting
Amana & Goodman HVAC Contact Information, Manuals & Flash-Light & Error Code De-coder are given here.
[Click to enlarge any image] Goodman Global and Goodman Manufacturing, founded in 1982, is currently (2017) a member of the Daikin Group, Osaka, Japan, after being purchased in 2012. Goodman produces residential and commercial HVAC equipment.
- Goodman HVAC Contact Information:
Goodman Heating & Air Conditioning, 7401 Security Way Houston, TX 77040 USA Tel: 1-877-254-4729 (USA) www.goodmanmfg.com - or - www.amana-hac.com
Website: http://www.goodmanmfg.com/
Goodman Global produces commercial room A/C units and other specialty cooling equipment sold for both residential and light-commercial use, producing equipment sild under these brands:
Amana, Goodman, QuietFlex, Daikin.
- SERVICE PARTS DEPARTMENT GOODMAN MANUFACTURING CO., LP 1501 SEAMIST HOUSTON, TEXAS 77008 USA Tel: (713) 861 - 2500
- Also see AMANA HVAC EQUIPMENT for manuals for older AMANA HVAC air conditioners etc.
Amana HVACR products that are manufactured by Goodman Global.
- Also see DAIKIN GLOBAL
- Also see Goodman's literature library at https://www.goodmanmfg.com/support/literature-library
Goodman Data Tag HVAC Age Decoder
- YYMM567890 where YY = year of manufacture and MM = month of manufacture
Amana & Goodman HVAC Manual Downloads
Free PDF downloads of Amana & Goodman HVAC equipment manuals are listed below, grouped by general type.
Amana / Goodman Air Conditioner & Heat Pump Manuals
- AMANA AM9C96 Two-Stage Gas Furnace USERS GUIDE [PDF]
- AMANA AM9C96 FURNACE SPECIFICATIONS [PDF] include a wiring diagram
- [PDF] (2017) ARUF - 14 & ASPT - 14
- AMANA GUCA GCCA CONDENSATE DRAIN LINES AND DRAIN TRAP INSTRUCTIONS (1998) pp. 29-32
- AMANA *M9S80*U Ultra Low NOx Gas Furnace Installation Instructions [PDF includes all of the Amana furnace EE & En error codes, beginninbg on p. 28
- GOODMAN AC SERIES 10-12 SEER CEILING-MOUNT AIR CONDITIONER [PDF] Manual
- l [PDF] AHCP service manual
- [PDF] (2013),
- [PDF] 2005-2009 R-22, GSC-series Goodman and Amana Brand split condenser units, ASC series, GSH series, ASH series, VSH series units.
- [PDF] 2006-2009 SX & SZ series blowers, coils, condensers\
- [PDF] (2006)
- GOODMAN R-22 CK-Series SERVICE INSTRUCTIONS [PDF] (2006) CKL CLJ CRT CLT TWC LQ HDC split system remote coolers & CPLE CPLJ CPRT CPLT HDP Split System remote heat pumps using R22, blower, coil, accessory repair
- Goodman SERVICE MANUAL RS610004 [PDF] Service Instructions Split System Air Conditioners and Split System Heat Pumps with R-22 Refrigerant Blowers, Coils, & Accessories
- GOODMAN Service Manual RS6200004 [PDF] Service and Troubleshooting ASXC, DSXC, and GSXC Condensing units, ASZC, DSZC, and GSZC Split System Heat Pumps with R-410A Refrigerant Blowers, Coils, & Accessories
Amana / Goodman Gas Furnace Manuals, Service Manuals & Recall Notices
- [PDF] (2007) Models: ACS, ACV, ADS, ADV, AMH, AMS, AMV, DCS, DDS, DHS, DMS, GCH, GCS, GDH, GDS, GCV, GHS, GKS, GME, GMH, GMS, GMV
- Goodman ADVC8/AMVC8 GMVC8 80% Gas Furnace Units MANUAL [PDF] (2010)
- [PDF] (2016)
- Goodman *CVC9/*MVC95 - VC9/*MVC95 - VC9/*MVC95 - TWO-STAGE GAS FURNACE Installation Instructions [PDF] (2009)
- GOODMAN ACVC9/AMVC95 GCVC9/GMVC95 TECHNICAL MANUAL [PDF] (2010) 90%-95% Gas Furnace Units
- GOODMAN TWO STAGE GAS FURNACE GDH8 TECHNICAL MANUAL [PDF] (2009) GDH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Dedicated Downflow Gas Furnace, Model Numbers: GDH80453AX* GDH80703AX* GDH80904BX* GDH81155CX*
Note: Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information for this furnace.
- [PDF] Installation & Operating Manual, (Type FSP CATEGORY IV Direct or Non Direct Vent Air Furnace)
- GOODMAN GAS FURNACE IO MANUAL GMP GMPE [PDF] power vented multi-position (2001) Goodman Manufacturing Company, LP 2550 North Loop West, Suite 400 Houston, Texas 77092 USA
This manual includes helpful chimney/vent sizing tables giving vent diameter, height, rise, and vent capacity.
- GOODMAN GAS FURNACE IO MANUAL GMS8 GDS8 GHS8 [PDF] (2005) Gas-Fired Warm Air Furnace, Single Stage, Category 1, Goodman Manufacturing Co., L.P.
- [PDF] (2019)
- GOODMAN FURNACE HIGH TEMPERATURE PLASTIC VENT HTPV SAFETY RECALL [Web article] US CPSC notice
- INTERTEK CVC96 7 MVC96 TWO STYAGE GAS FURNACE INSTALLATION INSTRUCTIONS (2016), Amana, Goodman Manufacturing, 5151 San Felipe Suite 500
Other Amana/Goodman HVAC Error Codes, Manuals, Parts Lists
- Also see this GOODMAN HVAC REPAIR PARTS CATALOG for GU*/GUE/GUH*/GUX Gas Furnaces [PDF]
- Also see - also see
- Also see INTERTEK / UTC Canada Corp, ICP Division
- Also see JANITROL HVAC
Watch out: see the US CPSC recall notice below as it involves 140,000 horizontal furnaces manufactured by Consolidated Industries - and reports of 50 fires. Note that there is no PSC has received more than 50 reports of fires associated with the 140,000 horizontal furnaces manufactured by Consolidated Industries Inc.
- US CPSC FURNACE RECALL: CONSOLIDATED INDUSTRIES HORIZONTAL FURNACES [PDF] (July 2001) [Note that there is currently (2022) no remedy available to consumers and the company that announced the recall is out of business.
Excerpts
WASHINGTON, D.C. - The U.S. Consumer Product Safety Commission (CPSC) is announcing a recall of about 30,000 furnaces sold in California. Seven firms are offering to repair or replace certain furnaces, which were sold under their own labels, but were manufactured by Consolidated Industries Inc.The units involved are gas-fired horizontal furnaces equipped with steel "NOx" rods installed above the burners and are commonly called NOx rod furnaces. These furnaces pose a substantial risk of fire.
All the furnaces can be identified by the steel rods installed above the burners. The firms participating in this recall are Amana Company, L.P., of Amana, Iowa; Bard Manufacturing, of Bryan, Ohio; Carrier Corporation, of Syracuse, N.Y.; Goettl Air Conditioning Inc., of Phoenix, Ariz.; Goodman Manufacturing Company L.P., of Houston, Texas; Heat Controller Inc., of Jackson, Mich.; and The Trane Company, a division of American Standard Inc., of Tyler, T
exas.
Goodman brands affected by this recall include: Franklin Electric Goodman GMC Hamilton Electric Janitrol Johnstone Liberty and Frunace Models: HBA 040 ND 3(X, RX, XC or RXC) HBA 060 ND 3(X, RX, XC or RXC) HBA 080 ND 4(X, RX, XC or RXC) HBA 100 ND 5(X, RX, XC or RXC) HBA 120 ND 5(X, RX, XC or RXC) HCA 040 ND 3(X, RX, XC or RXC) HCA 060 ND 3(X, RX, XC or RXC) HCA 080 ND 4(X, RX, XC or RXC) HCA 100 ND 5(X, RX, XC or RXC) HCA 120 ND 5(X, RX, XC or RXC) HCA 140 ND 5(X, RX, XC or RXC) HCC 040 ND 3(X, RX, XC or RXC) HCC 050 ND 3(X, RX, XC or RXC) HCC 060 ND 4(X, RX, XC or RXC) HCC 075 ND 4(X, RX, XC or RXC) HCC 080 ND 5(X, RX, XC or RXC) HCC 100 ND 5(X, RX, XC or RXC)
- Watch out: Also see Goodman Furnace High Temperature Plastic Vent HTPV SAFETY RECALL [Web Article] US CPSC notice
Amana & Goodman GMP & Other Gas Furnace Status Light Flash Fault Codes
A (usually red) LED is visible through an opening in the front of your Goodman furnace, typically just above a data tag. This table decodes the various LED lamp flash trouble codes.
Amana or Goodman Status Light / LED Error Codes | ||
Trouble Code Indicator | Meaning | Repair |
On Solid | No connection from the thermostat | Check thermostat wiring, setting, function |
1 Flash on/off | Furnace ignition failure Locks out after 3 ignition attempts. | Automatically resets after 1 hour. or Turn off power or turn down thermostat for 30 seconds then restore power / thermostat setting |
2 Flashes | Draft inducer / blower failure or pressure switch failure (short circuit) | Check for shorted wires; Replace pressure switch. |
3 Flashes | Open pressure switch circuit or draft inducer running when it should not be. Heating mode: The vent pressure (vacuum) switch will close when it detects a pressure in excess of it’s setting. If the pressure switch fails to close the status light will flash three (3) times. The sequence cannot continue until the pressure switch closes. | Check pressure switch hose for crimping; Check for improper or loose wiring. Replace failed pressure switch. |
4 Flashes | Primary limit circuit open or Amana: Pressure issue, high limit cuts furnace off. | Bad, loose, corroded electrical connection, Dirty air filter, Clean or replace air filters. Blocked exhaust flue: Safety check exhaust flue. Check flue, draft, combustion air. Check for clogged condensate drains. Check/replace open/faulty fan limit control. |
5 Flashes | Flame present but no call for heat | Check for gas leaks Check for improper / delayed burner shut-down Check for sticking gas valve & replace it if faulty. Watch out: this is an unsafe heater that should be left OFF pending repair. |
6 Flashes | Reversed polarity (some models) | Check power supply wiring vs wiring diagram |
7 Flashes | Low flame or weak flame sensor signal | Check gas supply pressure vs data plate pressure Check / replace dirty corroded flame sensor probe Check flame sensor mounting/location to be sure sensor is in the flame. |
8 Flashes | Igniter circuit failure | Check igniter wiring connections; check for bad ground connection; Replace defective igniter. |
9 Flashes | Open high state pressure switch Switch not closing during high-stage draft inducer blower operation | Inspect pressure switch hose for crimping Check for loose electrical connection at switch |
Continuous rapid flashing | 120VAC power supply polarity reversed | Check wiring diagram; fix wiring polarity |
...
Reader Comments, Questions & Answers About The Article Above
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
Reader Q&A - also see
On 2023-01-10 - by (mod) -
Mom124
We found parts lists for older Goodman GU-series heaters - now available above on this page, but I've not found the IO manual for the GUE040 heater - I'll continue to look and post whatever we can find here.
On 2023-01-10 - by Mom124
The Goodman website doesn't have any information about my much older model, GUE040-3. Does anyone have any info (esp manuals!) about this furnace model?
On 2019-12-15 - by (mod) -
Anon
You can download a Goodman GMH95 manual [PDF] here at https://inspectapedia.com/heat/Goodman-gmh950904-Manual.pdf
On 2019-12-15 by Anonymous
Manual gmh950904cxac
...
Continue reading at or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
Recommended Articles
- AGE of WATER HEATERS - data tag decoding, contact information for water heater manufacturers, water heater manuals
- AGE of HEATERS, BOILERS, FURNACES
- - home
- BOILERS, HEATING - home
- DATA TAGS on AIR CONDITIONERS for help decoding the equipment age and other specification
- FURNACES, HEATING - home
- Goodman HTPV RECALL
- in Spanish
- - home - Master Index to All Brand Names & HVAC manuals, wiring diagrams, installation and repair guides
Suggested citation for this web page
at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
INDEX to RELATED ARTICLES:
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
INDEX to RELATED ARTICLES: ARTICLE INDEX to HEATING SYSTEMS
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
Comment Form is loading comments...
Citations & References
In addition to any citations in the article above, a full list is available on request.
- In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
CONTINUE READING or RECOMMENDED ARTICLES.
- Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The HOME REFERENCE BOOK- the Encyclopedia of Homes and to use illustrations from The ILLUSTRATED HOME .
Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.